Detecting the location of leakages in the building envelope is useful in order to reduce the leakage area of the envelope and/or to estimate the leakage distribution of buildings [2]. Blower doors are very useful to find leaks [1]. The …Continue reading →
The recommended calibration for building airtightness measuring devices should follow the manufacturers recommendation as well as the governing body or standard being adhered to. The recommended calibration for building airtightness measuring devices depends on the manufacturer’s specifications. It is typically …Continue reading →
Existing methods to estimate building airtightness include: Fan pressurization, multi point test Fan pressurization, single point test Pulse test Tracer gas test Fan pressurization, multi point [1],[2] From a multi point pressurization test the airflow through the leakages in the building …Continue reading →
Calibration is the comparison of measurement values delivered by a device under test with those of a calibration standard of known accuracy. Such a standard could be another measurement device of known accuracy, a device generating the quantity to be …Continue reading →
A calibration should be carried out by an ISO/IEC 17025 accredited lab. Sometimes in some specific context it is allowed to have the calibration done by: a lab that has standards traceable to ISO/IEC 17025 accredited calibrations the manufacturer the …Continue reading →
Wind creates a heterogeneous pressure distribution around the building and induces a pressure difference between indoor and outdoor even when the fan is turned off. The impact of wind can be partly compensated by measuring and subtracting this zero-flow pressure and …Continue reading →
Duct tester systems designed to conduct air tightness tests on duct systems can sometimes be used to test building air tightness. The fans used in these systems have a much lower flow capacity than a standard blower door system, which means …Continue reading →
In most European countries the building preparation is based on ISO 9972 requirements. However, the interpretation of these requirements may differ from one country to another, and based on different building preparation rules. Building preparation errors are probably the dominant …Continue reading →
A blower door is a device used to measure the airtightness of buildings. It can also be used to measure air leakage between building zones, to locate leaks in ductwork and to help physically locate air leakage sites in the …Continue reading →