Building airtightness (also called envelope airtightness) is a general descriptive term expressing the resistance to inward or outward air leakage through unintentional leakage points or areas in the building envelope. This air leakage is driven by differential pressures across the …Continue reading →
Infiltration/exfiltration is the uncontrolled inward/outward leakage of outdoor/indoor air through air permeable materials, joints, cracks, interstices and other unintentional openings of a building envelope, caused by the pressure effects of wind, the stack effect or operation of HVAC-systems [1]. Infiltration/exfiltration causes convective …Continue reading →
The airtightness of a building is quantified by means of the measured air leakage rate through the building’s envelope in m³/h at a given reference pressure difference, often 50 Pa. The building airtightness may be expressed by other quantities, derived …Continue reading →
n50 is a number used to quantify building airtightness. It gives the air change rate occurring as a result of air leakage through the building envelope when an air pressure difference of 50 Pa exists between inside and outside. This …Continue reading →